NIST deprecates RSA-2048 from 2030. Find every one of them before attackers do.
🛡️
Not in CISA KEV
CRITICAL severity

CVE-2026-135789 — R95

CRITICAL

CVE-2026-135789 is a critical-severity (CVSS 9.1) CWE-77 vulnerability in d-link r95. The records list no fixed version yet; check the vendor advisory below and apply the mitigations in the meantime.

A security vulnerability has been detected in D-Link R95 101B06. Affected by this issue is the function GetBluetoothAdapterSettings/GetBluetoothBloodPressure/GetBluetoothDeviceList/GetBluetoothScanDeviceList/SetBluetoothAdapterSettings/SetBluetoothUnpairDevice/SetTriggerBluetoothScan/SetBluetoothPairDevice…

Published
Updated
Affected
1 product
Patched
See advisory
Exploits
None indexed
Exploitation data as of Nov 24, 2026 · OSV.dev, NVD, FIRST.org (EPSS)

Description

A security vulnerability has been detected in D-Link R95 101B06. Affected by this issue is the function GetBluetoothAdapterSettings/GetBluetoothBloodPressure/GetBluetoothDeviceList/GetBluetoothScanDeviceList/SetBluetoothAdapterSettings/SetBluetoothUnpairDevice/SetTriggerBluetoothScan/SetBluetoothPairDevice of the file /bin/ssi of the component DHMAPI SOAP Handler. The manipulation of the argument inner_xml leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.

Affected Products

1 product · 1 configurations
Hardware
r95d-link
all

Detection & mitigation playbook

Vendor / appliance
  1. Detect

    Inventory every d-link r95 deployment and check each version against the affected-products list above.

  2. Remediation status

    The records we use list no fixed version for CVE-2026-135789. Check the d-link r95 advisory for a patched release, and apply the workarounds below until you can upgrade.

  3. Mitigate without a patch

    Stop passing untrusted input into the interpreter or shell: call the affected binary with an argument array rather than a composed command string, reject anything outside a strict allowlist of expected values, and run the component under an account that cannot reach beyond the work it legitimately does. Alongside that, restrict the management interface to trusted networks and apply the vendor's recommended configuration mitigations.

Frequently Asked Questions

A security vulnerability has been detected in D-Link R95 101B06. Affected by this issue is the function GetBluetoothAdapterSettings/GetBluetoothBloodPressure/GetBluetoothDeviceList/GetBluetoothScanDeviceList/SetBluetoothAdapterSettings/SetBluetoothUnpairDevice/SetTriggerBluetoothScan/SetBluetoothPairDevice of the file /bin/ssi of the component DHMAPI SOAP Handler. The manipulation of the argument inner_xml leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.
O3 Security · Runtime Protection

Is CVE-2026-135789 being exploited in your environment?

Detect and block the exploit chain at execution, on systems you cannot patch yet.