Your RSA-2048 keys break in 2030. Find every one of them before attackers do.
🛡️
Not in CISA KEV
HIGH severity

CVE-2026-110124 — Kerwincui

HIGH

CVE-2026-110124 is a high-severity (CVSS 8.1) CWE-639 vulnerability. No vendor fix is recorded yet; mitigation options are listed below.

FastBee through 2.1.0 contains an insecure direct object reference vulnerability in DeviceController that allows authenticated low-privilege users to read and modify other tenants'…

Published
Updated
Affected
—
Patched
—
Exploits
None indexed
Exploitation data as of Oct 14, 2026 · OSV.dev, NVD, FIRST.org (EPSS)

Exploitation Status

Proof-of-concept exploit code exists

  • CISA’s SSVC triage found public proof-of-concept exploit code for this CVE, though no confirmed active exploitation.
  • A successful exploit gives an attacker total control of the affected component, not partial access.

Exploitation and automatability from CISA’s SSVC triage for CVE-2026-110124.

EPSS Exploitation Probability

via FIRST.org ↗
0.3%probability of exploitation in next 30 days
Lower Risk0.00%
Lower risk than most CVEs22th percentile — riskier than 22% of all scored CVEsHighest risk

Probability of exploitation in the next 30 days, from FIRST.org EPSS.

How urgent is this, really

CVE-2026-110124 by exploitation likelihood (EPSS) against impact (CVSS). Outside the shaded patch-first corner.

Where this sits among everything scored

Of 385,987 CVEs with a current EPSS score, this one falls in the < 10% band (highlighted). Counts from FIRST.org, log-scaled.

Description

FastBee through 2.1.0 contains an insecure direct object reference vulnerability in DeviceController that allows authenticated low-privilege users to read and modify other tenants' devices by supplying sequential device IDs. Self-registered attackers can enumerate deviceId or serialNumber values to read owner, IP, and location data, and overwrite user_id and tenant_id to take over devices.

Detection & mitigation playbook

Vulnerability
  1. Detect

    Identify every host running the affected component and compare the installed build against the fixed version below — for source-built or distro-packaged software the version string, not a lockfile, is the source of truth (`dpkg -l`, `rpm -q`, or the binary's own `--version`).

  2. Remediation status

    No fixed release is recorded for CVE-2026-110124 yet. Track the upstream advisory, and apply the exposure-reduction steps below in the meantime.

  3. Mitigate without a patch

    If you can't upgrade right away: gate or disable the affected feature, validate untrusted input at the boundary, and avoid passing attacker-controlled data into the vulnerable path. O3's runtime protection blocks exploitation in production as an interim safeguard until the upgrade lands.

Frequently Asked Questions

FastBee through 2.1.0 contains an insecure direct object reference vulnerability in DeviceController that allows authenticated low-privilege users to read and modify other tenants' devices by supplying sequential device IDs. Self-registered attackers can enumerate deviceId or serialNumber values to read owner, IP, and location data, and overwrite user_id and tenant_id to take over devices.
O3 Security · Impact-Aware SCA

Is CVE-2026-110124 in your dependencies?

Find it across , including transitive dependencies.