NIST deprecates RSA-2048 from 2030. Find every one of them before attackers do.
🐹 Go
Not in CISA KEV

CVE-2025-67713 — miniflux.app

Fix: miniflux/v2@76df99f

CVE-2025-67713 is a Open Redirect vulnerability in miniflux.app/v2. A fix is available for miniflux.app/v2 — see the affected versions and patch details below.

Miniflux 2 has an Open Redirect via protocol-relative `redirect_url`

Also known asGHSA-wqv2-4wpg-8hc9GO-2025-4226
Published
Updated
Affected
1 pkg
Patched
1 / 1
Exploits
None indexed
Exploitation data as of Nov 6, 2026 · OSV.dev, NVD, FIRST.org (EPSS)

Exploitation Status

Proof-of-concept exploit code exists

  • CISA’s SSVC triage found public proof-of-concept exploit code for this CVE, though no confirmed active exploitation.

Exploitation and automatability from CISA’s SSVC triage for CVE-2025-67713.

EPSS Exploitation Probability

via FIRST.org ↗
0.2%probability of exploitation in next 30 days
Lower Risk0.00%
Lower risk than most CVEs13th percentile — riskier than 13% of all scored CVEsHighest risk
0.00%0.24%0.48%0.72%0.1%0.2%May 26Sep 26Nov 26

Probability of exploitation in the next 30 days, from FIRST.org EPSS.

Real-World Exposure

1 pkg affected
🐹miniflux.app/v2

Real-time download stats are indexed for npm and PyPI packages. This vulnerability affects Go packages — download data is not available via public APIs for these ecosystems.

Description

Summary

redirect_url is treated as safe when url.Parse(...).IsAbs() is false. Protocol-relative URLs like //ikotaslabs.com have an empty scheme and pass that check, allowing post-login redirects to attacker-controlled sites.

Details

  • url.Parse("//ikotaslabs.com") => empty Scheme, Host="ikotaslabs.com".
  • IsAbs() returns false for //ikotaslabs.com, so the code treats it as allowed.
  • Browser resolves //ikotaslabs.com to current-origin scheme (e.g. https://ikotaslabs.com), enabling phishing flows after login.

PoC

  1. Send or visit: http://localhost/login?redirect_url=//ikotaslabs.com
  2. Complete normal login flow.
  3. After login the app redirects to https://ikotaslabs.com (or http:// depending on origin).

Acknowledgements

This vulnerability was discovered using the automated vulnerability analysis tools VulScribe and PwnML. The research and tool development were conducted with support from the MITOU Advanced Program (未踏アドバンスト事業), implemented by the Information-technology Promotion Agency (IPA), Japan.

Affected Packages

1 total 1 fixed
EcosystemPackageVulnerable rangeFix
🐹Gominiflux.app/v2all versions2.2.15go get miniflux.app/v2@v2.2.15

Affected Products

1 product · 1 configurations
Application
minifluxminiflux_project
< 2.2.15
range

Detection & mitigation playbook

Open-source dependency
  1. Detect

    Scan your dependency tree (package-lock.json, pnpm-lock.yaml, requirements.txt, go.sum, etc.) for miniflux.app/v2, including transitive dependencies — a direct dependency you never call can still pull in a vulnerable version.

  2. Fix

    Update miniflux.app/v2 to 2.2.15 or later, then make sure no transitive (indirect) dependency still pins the vulnerable range — O3 confirms CVE-2025-67713 is resolved across your whole dependency graph.

  3. Workarounds

    Stop reflecting attacker-controlled destinations: resolve every redirect target against an allowlist of paths or hosts you own, prefer a server-side key over a full URL in the request, and reject absolute URLs entirely where the flow only ever needs a relative one.

Frequently Asked Questions

### Summary `redirect_url` is treated as safe when `url.Parse(...).IsAbs()` is false. Protocol-relative URLs like `//ikotaslabs.com` have an empty scheme and pass that check, allowing post-login redirects to attacker-controlled sites. ### Details - `url.Parse("//ikotaslabs.com")` => empty Scheme, Host="ikotaslabs.com". - `IsAbs()` returns false for `//ikotaslabs.com`, so the code treats it as allowed. - Browser resolves `//ikotaslabs.com` to current-origin scheme (e.g. `https://ikotaslabs.com`), enabling phishing flows after login. ### PoC 1. Send or visit: `http://localhost/login?redirect_u
O3 Security · Impact-Aware SCA

Is CVE-2025-67713 in your dependencies?

Find it across Go, including transitive dependencies.

CVE-2025-67713: miniflux.app — Fixed in 2.2.15