CVE-2025-67713 — miniflux.app
Fix: miniflux/v2@76df99fCVE-2025-67713 is a Open Redirect vulnerability in miniflux.app/v2. A fix is available for miniflux.app/v2 — see the affected versions and patch details below.
Miniflux 2 has an Open Redirect via protocol-relative `redirect_url`
Exploitation Status
Proof-of-concept exploit code exists
- CISA’s SSVC triage found public proof-of-concept exploit code for this CVE, though no confirmed active exploitation.
Exploitation and automatability from CISA’s SSVC triage for CVE-2025-67713.
EPSS Exploitation Probability
Probability of exploitation in the next 30 days, from FIRST.org EPSS.
Real-World Exposure
miniflux.app/v2Real-time download stats are indexed for npm and PyPI packages. This vulnerability affects Go packages — download data is not available via public APIs for these ecosystems.
Description
Summary
redirect_url is treated as safe when url.Parse(...).IsAbs() is false. Protocol-relative URLs like //ikotaslabs.com have an empty scheme and pass that check, allowing post-login redirects to attacker-controlled sites.
Details
url.Parse("//ikotaslabs.com")=> empty Scheme, Host="ikotaslabs.com".IsAbs()returns false for//ikotaslabs.com, so the code treats it as allowed.- Browser resolves
//ikotaslabs.comto current-origin scheme (e.g.https://ikotaslabs.com), enabling phishing flows after login.
PoC
- Send or visit:
http://localhost/login?redirect_url=//ikotaslabs.com - Complete normal login flow.
- After login the app redirects to
https://ikotaslabs.com(orhttp://depending on origin).
Acknowledgements
This vulnerability was discovered using the automated vulnerability analysis tools VulScribe and PwnML. The research and tool development were conducted with support from the MITOU Advanced Program (未踏アドバンスト事業), implemented by the Information-technology Promotion Agency (IPA), Japan.
Affected Packages
| Ecosystem | Package | Vulnerable range | Fix |
|---|---|---|---|
| 🐹Go | miniflux.app/v2 | all versions | 2.2.15go get miniflux.app/v2@v2.2.15 |
Affected Products
minifluxminiflux_projectDetection & mitigation playbook
Open-source dependencyDetect
Scan your dependency tree (package-lock.json, pnpm-lock.yaml, requirements.txt, go.sum, etc.) for miniflux.app/v2, including transitive dependencies — a direct dependency you never call can still pull in a vulnerable version.
Fix
Update miniflux.app/v2 to 2.2.15 or later, then make sure no transitive (indirect) dependency still pins the vulnerable range — O3 confirms CVE-2025-67713 is resolved across your whole dependency graph.
Workarounds
Stop reflecting attacker-controlled destinations: resolve every redirect target against an allowlist of paths or hosts you own, prefer a server-side key over a full URL in the request, and reject absolute URLs entirely where the flow only ever needs a relative one.
Frequently Asked Questions
Is CVE-2025-67713 in your dependencies?
Find it across Go, including transitive dependencies.