CVE-2025-29635 — Mono7s
HIGHCVE-2025-29635 is a high-severity (CVSS 7.2) CWE-77 vulnerability. It is in CISA's Known Exploited Vulnerabilities catalog (added 2026-04-24) — treat it as actively exploited and patch now. No vendor fix is recorded yet; mitigation options are listed below.
A command injection vulnerability in D-Link DIR-823X 240126 and 240802 allows an authorized attacker to execute arbitrary commands on remote devices by sending a POST request to /goform/set_prohibiting…
Exploitation Status
Actively exploited in the wild
- Confirmed by CISA's Known Exploited Vulnerabilities catalog on 2026-04-24. Federal agencies were required to remediate by 2026-05-08.
- A successful exploit gives an attacker total control of the affected component, not partial access.
Exploitation and automatability from CISA (KEV catalog and SSVC triage) for CVE-2025-29635.
EPSS Exploitation Probability
Probability of exploitation in the next 30 days, from FIRST.org EPSS.
How urgent is this, really
CVE-2025-29635 by exploitation likelihood (EPSS) against impact (CVSS). In the shaded patch-first corner (EPSS 50%+, CVSS 7.0+).
Where this sits among everything scored
Of 395,249 CVEs with a current EPSS score, this one falls in the 50–90% band (highlighted). Counts from FIRST.org, log-scaled.
Description
A command injection vulnerability in D-Link DIR-823X 240126 and 240802 allows an authorized attacker to execute arbitrary commands on remote devices by sending a POST request to /goform/set_prohibiting via the corresponding function, triggering remote command execution.
Affected Products
dir-823x firmwaredlinkDetection & mitigation playbook
VulnerabilityDetect
Identify every host running the affected component and compare the installed build against the fixed version below — for source-built or distro-packaged software the version string, not a lockfile, is the source of truth (`dpkg -l`, `rpm -q`, or the binary's own `--version`).
Remediation status
No fixed release is recorded for CVE-2025-29635 yet. Track the upstream advisory, and apply the exposure-reduction steps below in the meantime.
Mitigate without a patch
Stop passing untrusted input into the interpreter or shell: call the affected binary with an argument array rather than a composed command string, reject anything outside a strict allowlist of expected values, and run the component under an account that cannot reach beyond the work it legitimately does.
How to detect CVE-2025-29635
A community-maintained Nuclei template exists for this CVE. You can scan for it directly:
nuclei -id cve-2025-29635 -u https://target- Template
- D-Link DIR-823X set_prohibiting - Command Injection
- Severity
- high
- Impact
- Attackers can execute arbitrary commands on the device remotely, potentially leading to full device compromise.
- Remediation
- Update to the latest firmware version provided by D-Link or contact vendor for patches.
Template by ProjectDiscovery nuclei-templates (pussycat0x), MIT licensed. View the full template. Scan only systems you are authorised to test.
Frequently Asked Questions
Is CVE-2025-29635 in your dependencies?
Find it across , including transitive dependencies.