Your RSA-2048 keys break in 2030. Find every one of them before attackers do.

CVE-2023-4570

HIGH

CVE-2023-4570 is a high-severity (CVSS 8.8) CWE-420 vulnerability in ni measurementlink. O3 Security detects and blocks CVE-2023-4570 exploitation at runtime via eBPF exploit-chain detection and L7 egress monitoring, even on unpatched systems.

An improper access restriction in NI MeasurementLink Python services could allow an attacker on an adjacent network to reach services exposed on localhost. These services were previously…

Published
Oct 5, 2023
Updated
Jun 17, 2026
Affected
1 product
Patched
See advisory
Exploits
None indexed

Description

An improper access restriction in NI MeasurementLink Python services could allow an attacker on an adjacent network to reach services exposed on localhost. These services were previously thought to be unreachable outside of the node. This affects measurement plug-ins written in Python using version 1.1.0 of the ni-measurementlink-service Python package and all previous versions.

Affected Products

1 product · 1 configurations
Application
measurementlinkni
≥ 1.0.0 && < 1.1.1
range

Detection & mitigation playbook

Vendor / appliance
  1. Detect

    Inventory every ni measurementlink deployment and check each version against the affected-products list above. Because the exploit targets the running system rather than your application code, also watch for exploitation at the network and runtime layer — O3 flags the exploit behaviour from runtime telemetry and egress traffic even before a vulnerable build is confirmed.

  2. Fix

    Apply the ni measurementlink security patch or hotfix for CVE-2023-4570 on the affected version, following the vendor advisory for your exact build.

  3. Workarounds

    Cut exposure now: restrict the management/admin interface to trusted networks, segment the device, and apply the vendor's recommended configuration mitigations and any WAF/IPS signature. O3's runtime protection blocks the exploit chain at execution, holding the line on unpatched or end-of-life systems until you can patch.

  4. How O3 protects you

    O3 detects and blocks CVE-2023-4570 exploitation at runtime: eBPF exploit-chain detection, plus L7 egress monitoring that catches the post-exploitation callback and severs the attacker's outbound channel.

Tailored to CVE-2023-4570. Runtime protection reduces exposure until a permanent patch is applied and verified — it complements patching, it doesn't replace it.

Frequently Asked Questions

An improper access restriction in NI MeasurementLink Python services could allow an attacker on an adjacent network to reach services exposed on localhost. These services were previously thought to be unreachable outside of the node. This affects measurement plug-ins written in Python using version 1.1.0 of the ni-measurementlink-service Python package and all previous versions.
O3 Security · Runtime Protection

Is CVE-2023-4570 being exploited in your environment?

O3's eBPF runtime sensors and L7 egress monitoring detect and block the CVE-2023-4570 exploit chain at execution — protecting unpatched and end-of-life systems until the vendor patch is applied.