CVE-2022-36553 — Nwqda
CVE-2022-36553 is a CWE-77 vulnerability. 2 public exploit references exist, so weaponization risk is real. No vendor fix is recorded yet; mitigation options are listed below.
Hytec Inter HWL-2511-SS v1.05 and below was discovered to contain a command injection vulnerability via the component /www/cgi-bin/popen.cgi.
EPSS Exploitation Probability
Probability of exploitation in the next 30 days, from FIRST.org EPSS.
Description
Hytec Inter HWL-2511-SS v1.05 and below was discovered to contain a command injection vulnerability via the component /www/cgi-bin/popen.cgi.
Affected Products
hwl-2511-ss firmwarehytecResearch use only. For defensive security, authorized penetration testing, and academic research only. Never execute exploit code against systems without explicit written authorization.
Detection & mitigation playbook
VulnerabilityDetect
Identify every host running the affected component and compare the installed build against the fixed version below — for source-built or distro-packaged software the version string, not a lockfile, is the source of truth (`dpkg -l`, `rpm -q`, or the binary's own `--version`).
Remediation status
No fixed release is recorded for CVE-2022-36553 yet. Track the upstream advisory, and apply the exposure-reduction steps below in the meantime.
Mitigate without a patch
Stop passing untrusted input into the interpreter or shell: call the affected binary with an argument array rather than a composed command string, reject anything outside a strict allowlist of expected values, and run the component under an account that cannot reach beyond the work it legitimately does.
How to detect CVE-2022-36553
A community-maintained Nuclei template exists for this CVE. You can scan for it directly:
nuclei -id cve-2022-36553 -u https://target- Template
- Hytec Inter HWL-2511-SS - Remote Command Execution
- Severity
- critical
- Impact
- Unauthenticated attackers can execute arbitrary commands on the Hytec Inter HWL-2511-SS cellular router through command injection in the popen.cgi endpoint, potentially gaining complete control over the device and connected network infrastructure.
- Remediation
- Update Hytec Inter HWL-2511-SS firmware to a version later than 1.05 that properly sanitizes command parameters in popen.cgi.
Template by ProjectDiscovery nuclei-templates (HuTa0), MIT licensed. View the full template. Scan only systems you are authorised to test.
Frequently Asked Questions
Is CVE-2022-36553 in your dependencies?
Find it across , including transitive dependencies.