NIST deprecates RSA-2048 from 2030. Find every one of them before attackers do.
Not in CISA KEV

OpenEMR before 8.5.0 Improper Authorization in Lab Order Transmission via list_reports.phpGHSA-3xjm-656g-cfj5

GHSA-3xjm-656g-cfj5 is a CWE-863 vulnerability. A fix is available — see the affected versions and patch details below.

Published
Updated
Affected
1 product
Patched
See advisory
Exploits
None indexed
Exploitation data as of Nov 17, 2026 · OSV.dev, NVD, FIRST.org (EPSS)

Exploitation Status

Proof-of-concept exploit code exists

  • CISA’s SSVC triage found public proof-of-concept exploit code for this CVE, though no confirmed active exploitation.

Exploitation and automatability from CISA’s SSVC triage for GHSA-3xjm-656g-cfj5.

EPSS Exploitation Probability

via FIRST.org ↗
0.3%probability of exploitation in next 30 days
Lower Risk0.00%
Lower risk than most CVEs25th percentile — riskier than 25% of all scored CVEsHighest risk

Probability of exploitation in the next 30 days, from FIRST.org EPSS.

Description

OpenEMR before 8.5.0 contains an improper authorization vulnerability in interface/orders/list_reports.php that allows read-only users to transmit lab orders because the patients/med check ignores write permission. Authenticated attackers can submit form_xmit with arbitrary procedure order IDs to send HL7 orders containing SSNs, insurance, and diagnoses to laboratories and mark them transmitted.

Affected Products

1 product · 1 configurations
Application
openemropen-emr
< 8.5.0
range

Detection & mitigation playbook

Vulnerability
  1. Detect

    Identify every host running the affected component and compare the installed build against the fixed version below — for source-built or distro-packaged software the version string, not a lockfile, is the source of truth (`dpkg -l`, `rpm -q`, or the binary's own `--version`).

  2. Fix

    Upgrade the affected component to the fixed release for GHSA-3xjm-656g-cfj5, or apply your distribution's backported patch — distro builds are often patched at an older version number, so check your vendor's advisory rather than the upstream version alone.

  3. Workarounds

    Put an independent control in front of the weakness: restrict the affected endpoint or interface to trusted networks, require an additional authentication factor or proxy-level check, and invalidate existing sessions and credentials in case the flaw has already been used.

Frequently Asked Questions

OpenEMR before 8.5.0 contains an improper authorization vulnerability in interface/orders/list_reports.php that allows read-only users to transmit lab orders because the patients/med check ignores write permission. Authenticated attackers can submit form_xmit with arbitrary procedure order IDs to send HL7 orders containing SSNs, insurance, and diagnoses to laboratories and mark them transmitted.
O3 Security · Impact-Aware SCA

Is GHSA-3xjm-656g-cfj5 in your dependencies?

Find it across your dependency tree, including transitive dependencies.

OpenEMR before 8.5.0 Improper Authorization in Lab…