Your RSA-2048 keys break in 2030. Find every one of them before attackers do.

CVE-2026-54413

HIGH

driftregion iso14229 through 0.9.0 contains an integer underflow and downstream out-of-bounds read in the Handle_0x27_SecurityAccess() function in iso14229.c that allows a remote unauthenticated…

Published
Jun 14, 2026
Updated
Jun 17, 2026
Affected
0 pkgs
Patched
None yet
Exploits
None indexed

EPSS Exploitation Probability

via FIRST.org ↗
0.5%probability of exploitation in next 30 days
Lower Risk37th percentile0.00%

EPSS (Exploit Prediction Scoring System) is a daily probability model maintained by FIRST.org. It estimates the likelihood a CVE will be exploited in production environments within the next 30 days, derived from real-world threat intelligence signals.

Description

driftregion iso14229 through 0.9.0 contains an integer underflow and downstream out-of-bounds read in the Handle_0x27_SecurityAccess() function in iso14229.c that allows a remote unauthenticated attacker to crash a UDS server and potentially read memory past the receive buffer by sending a single-byte 0x27 SecurityAccess request that follows any earlier well-formed 0x27 message. The handler reads the SecurityAccess subFunction from recv_buf[1] without first checking that recv_len is at least 2, then computes the key-data length as the unsigned subtraction (uint16_t)(recv_len - UDS_0X27_REQ_BASE_LEN); when recv_len equals 1 the result underflows to 65535 and is passed as args.len to the application's SecAccessValidateKey or SecAccessRequestSeed callback, which typically iterates or copies that many bytes from the 4-KB receive buffer. Every other UDS sub-function handler in the library (0x10, 0x11, 0x14, 0x19, 0x22, 0x23, 0x28, and others) performs an explicit recv_len lower-bound check before indexing; Handle_0x27_SecurityAccess is the sole outlier. The vulnerable handler reaches over CAN bus, OBD-II, ISO-TP, and DoIP transports and is exposed in the default diagnostic session without prior authentication; deployments on automotive ECUs, industrial controllers, and IoT devices that ship iso14229 as their UDS server are affected.

Detection & mitigation playbook

Vulnerability
  1. Detect

    Scan your dependency tree (package-lock.json, pnpm-lock.yaml, requirements.txt, go.sum, etc.) for the affected component. O3's reachability analysis confirms whether the vulnerable code path is actually invoked in your application, so you act on real exposure instead of every transitive match.

  2. Remediation status

    No patched version of the affected component has shipped for CVE-2026-54413 yet. Where your build allows, override or pin the dependency away from the vulnerable range, and apply any maintainer-recommended mitigation.

  3. Mitigate without a patch

    If you can't upgrade right away: gate or disable the affected feature, validate untrusted input at the boundary, and avoid passing attacker-controlled data into the vulnerable path. O3's runtime protection blocks exploitation in production as an interim safeguard until the upgrade lands.

  4. How O3 protects you

    O3 pinpoints whether CVE-2026-54413 is reachable in your code and exactly where to fix it, then blocks exploitation in production at runtime until the patched version is deployed.

Tailored to CVE-2026-54413. Runtime protection reduces exposure until a permanent patch is applied and verified — it complements patching, it doesn't replace it.

Frequently Asked Questions

driftregion iso14229 through 0.9.0 contains an integer underflow and downstream out-of-bounds read in the Handle_0x27_SecurityAccess() function in iso14229.c that allows a remote unauthenticated attacker to crash a UDS server and potentially read memory past the receive buffer by sending a single-byte 0x27 SecurityAccess request that follows any earlier well-formed 0x27 message. The handler reads the SecurityAccess subFunction from recv_buf[1] without first checking that recv_len is at least 2, then computes the key-data length as the unsigned subtraction (uint16_t)(recv_len - UDS_0X27_REQ_BAS
O3 Security · Impact-Aware SCA

Is CVE-2026-54413 in your dependencies?

O3 detects CVE-2026-54413 across dependencies and uses function-level reachability to confirm whether the vulnerable code path is actually reachable — not just present. No false positives.