Your RSA-2048 keys break in 2030. Find every one of them before attackers do.
🛡️
Not in CISA KEV
CRITICAL severity

CVE-2026-50746

CRITICAL

CVE-2026-50746 is a critical-severity (CVSS 10) CWE-284 vulnerability. No vendor fix is recorded yet; mitigation options are listed below.

A malicious actor with access to the network could exploit an Improper Access Control vulnerability found in UniFi Connect Application to execute a Command Injection on the host device.

Published
Updated
Affected
1 product
Patched
See advisory
Exploits
None indexed
Exploitation data as of Oct 10, 2026 · OSV.dev, NVD, FIRST.org (EPSS)

Exploitation Status

No confirmed exploitation observed yet

  • CISA assesses this as automatable — exploitation doesn’t require manual, per-target effort, which raises the odds of mass scanning and opportunistic attacks.
  • A successful exploit gives an attacker total control of the affected component, not partial access.
  • CISA’s own triage has not observed active exploitation or public proof-of-concept code for this CVE as of its last assessment.

Exploitation and automatability from CISA’s SSVC triage for CVE-2026-50746.

EPSS Exploitation Probability

via FIRST.org ↗
1.7%probability of exploitation in next 30 days
Lower Risk0.00%
Lower risk than most CVEs76th percentile — riskier than 76% of all scored CVEsHighest risk
1.19%1.79%2.40%3.00%2.5%1.7%1.7%1.7%Aug 26Oct 26Oct 26

Probability of exploitation in the next 30 days, from FIRST.org EPSS.

How urgent is this, really

CVE-2026-50746 by exploitation likelihood (EPSS) against impact (CVSS). Outside the shaded patch-first corner.

Where this sits among everything scored

Of 385,386 CVEs with a current EPSS score, this one falls in the < 10% band (highlighted). Counts from FIRST.org, log-scaled.

Description

A malicious actor with access to the network could exploit an Improper Access Control vulnerability found in UniFi Connect Application to execute a Command Injection on the host device.

Affected Products

1 product · 1 configurations
Application
unifi connect applicationui
< 3.24.20
range

Detection & mitigation playbook

Vulnerability
  1. Detect

    Identify every host running the affected component and compare the installed build against the fixed version below — for source-built or distro-packaged software the version string, not a lockfile, is the source of truth (`dpkg -l`, `rpm -q`, or the binary's own `--version`).

  2. Remediation status

    No fixed release is recorded for CVE-2026-50746 yet. Track the upstream advisory, and apply the exposure-reduction steps below in the meantime.

  3. Mitigate without a patch

    Stop passing untrusted input into the interpreter or shell: call the affected binary with an argument array rather than a composed command string, reject anything outside a strict allowlist of expected values, and run the component under an account that cannot reach beyond the work it legitimately does.

Frequently Asked Questions

A malicious actor with access to the network could exploit an Improper Access Control vulnerability found in UniFi Connect Application to execute a Command Injection on the host device.
O3 Security · Impact-Aware SCA

Is CVE-2026-50746 in your dependencies?

Find it across , including transitive dependencies.

CVE-2026-50746: Critical 10 severity