Your RSA-2048 keys break in 2030. Find every one of them before attackers do.

CVE-2026-49494

HIGH

Xcitium Client Security (XCS) before 13.8.2.10019 and Comodo Internet Security (CIS) through 12.3.4.8162 (fix expected by 2026 Q3) contain an integer underflow vulnerability in the…

Published
Jun 7, 2026
Updated
Jun 23, 2026
Affected
0 pkgs
Patched
None yet
Exploits
None indexed

EPSS Exploitation Probability

via FIRST.org ↗
0.5%probability of exploitation in next 30 days
Lower Risk41th percentile0.00%

EPSS (Exploit Prediction Scoring System) is a daily probability model maintained by FIRST.org. It estimates the likelihood a CVE will be exploited in production environments within the next 30 days, derived from real-world threat intelligence signals.

Description

Xcitium Client Security (XCS) before 13.8.2.10019 and Comodo Internet Security (CIS) through 12.3.4.8162 (fix expected by 2026 Q3) contain an integer underflow vulnerability in the firewall driver Inspect.sys that allows remote unauthenticated attackers to crash the system by sending a crafted IPv6 packet with a declared payload length smaller than the sum of its extension-header lengths. The unsigned 64-bit payload-length value underflows to a near-maximal integer, triggering an out-of-bounds read and oversized memcpy in the Windows kernel at DISPATCH_LEVEL, resulting in a blue screen of death even on hosts with all ports blocked.

Detection & mitigation playbook

Vulnerability
  1. Detect

    Scan your dependency tree (package-lock.json, pnpm-lock.yaml, requirements.txt, go.sum, etc.) for the affected component. O3's reachability analysis confirms whether the vulnerable code path is actually invoked in your application, so you act on real exposure instead of every transitive match.

  2. Remediation status

    No patched version of the affected component has shipped for CVE-2026-49494 yet. Where your build allows, override or pin the dependency away from the vulnerable range, and apply any maintainer-recommended mitigation.

  3. Mitigate without a patch

    If you can't upgrade right away: gate or disable the affected feature, validate untrusted input at the boundary, and avoid passing attacker-controlled data into the vulnerable path. O3's runtime protection blocks exploitation in production as an interim safeguard until the upgrade lands.

  4. How O3 protects you

    O3 pinpoints whether CVE-2026-49494 is reachable in your code and exactly where to fix it, then blocks exploitation in production at runtime until the patched version is deployed.

Tailored to CVE-2026-49494. Runtime protection reduces exposure until a permanent patch is applied and verified — it complements patching, it doesn't replace it.

Frequently Asked Questions

Xcitium Client Security (XCS) before 13.8.2.10019 and Comodo Internet Security (CIS) through 12.3.4.8162 (fix expected by 2026 Q3) contain an integer underflow vulnerability in the firewall driver Inspect.sys that allows remote unauthenticated attackers to crash the system by sending a crafted IPv6 packet with a declared payload length smaller than the sum of its extension-header lengths. The unsigned 64-bit payload-length value underflows to a near-maximal integer, triggering an out-of-bounds read and oversized memcpy in the Windows kernel at DISPATCH_LEVEL, resulting in a blue screen of deat
O3 Security · Impact-Aware SCA

Is CVE-2026-49494 in your dependencies?

O3 detects CVE-2026-49494 across dependencies and uses function-level reachability to confirm whether the vulnerable code path is actually reachable — not just present. No false positives.