CVE-2026-41176
CRITICALRclone is a command-line program to sync files and directories to and from different cloud storage providers. The RC endpoint `options/set` is exposed without `AuthRequired: true`,…
EPSS Exploitation Probability
EPSS (Exploit Prediction Scoring System) is a daily probability model maintained by FIRST.org. It estimates the likelihood a CVE will be exploited in production environments within the next 30 days, derived from real-world threat intelligence signals.
Description
Rclone is a command-line program to sync files and directories to and from different cloud storage providers. The RC endpoint options/set is exposed without AuthRequired: true, but it can mutate global runtime configuration, including the RC option block itself. Starting in version 1.45.0 and prior to version 1.73.5, an unauthenticated attacker can set rc.NoAuth=true, which disables the authorization gate for many RC methods registered with AuthRequired: true on reachable RC servers that are started without global HTTP authentication. This can lead to unauthorized access to sensitive administrative functionality, including configuration and operational RC methods. Version 1.73.5 patches the issue.
Affected Products
rclonercloneDetection & mitigation playbook
Vendor / applianceDetect
Inventory every rclone rclone deployment and check each version against the affected-products list above. Because the exploit targets the running system rather than your application code, also watch for exploitation at the network and runtime layer — O3 flags the exploit behaviour from runtime telemetry and egress traffic even before a vulnerable build is confirmed.
Fix
Apply the rclone rclone security patch or hotfix for CVE-2026-41176 on the affected version, following the vendor advisory for your exact build.
Workarounds
Cut exposure now: restrict the management/admin interface to trusted networks, segment the device, and apply the vendor's recommended configuration mitigations and any WAF/IPS signature. O3's runtime protection blocks the exploit chain at execution, holding the line on unpatched or end-of-life systems until you can patch.
How O3 protects you
O3 detects and blocks CVE-2026-41176 exploitation at runtime: eBPF exploit-chain detection, plus L7 egress monitoring that catches the post-exploitation callback and severs the attacker's outbound channel.
Tailored to CVE-2026-41176. Runtime protection reduces exposure until a permanent patch is applied and verified — it complements patching, it doesn't replace it.
Frequently Asked Questions
Is CVE-2026-41176 being exploited in your environment?
O3's eBPF runtime sensors and L7 egress monitoring detect and block the CVE-2026-41176 exploit chain at execution — protecting unpatched and end-of-life systems until the vendor patch is applied.