CVE-2024-8957 — Pt30x-Ndi Firmware
HIGHCVE-2024-8957 is a high-severity (CVSS 7.2) OS Command Injection vulnerability in ptzoptics pt30x-ndi firmware. It is in CISA's Known Exploited Vulnerabilities catalog (added 2024-11-04) — treat it as actively exploited and patch now. No vendor fix is recorded yet; mitigation options are listed below.
PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may…
Exploitation Status
Actively exploited in the wild
- Confirmed by CISA's Known Exploited Vulnerabilities catalog on 2024-11-04. Federal agencies were required to remediate by 2024-11-25.
- A successful exploit gives an attacker total control of the affected component, not partial access.
Exploitation and automatability from CISA (KEV catalog and SSVC triage) for CVE-2024-8957.
EPSS Exploitation Probability
Probability of exploitation in the next 30 days, from FIRST.org EPSS.
How urgent is this, really
CVE-2024-8957 by exploitation likelihood (EPSS) against impact (CVSS). In the shaded patch-first corner (EPSS 50%+, CVSS 7.0+).
Where this sits among everything scored
Of 395,249 CVEs with a current EPSS score, this one falls in the 50–90% band (highlighted). Counts from FIRST.org, log-scaled.
Description
PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.
Affected Products
pt30x-ndi firmwareptzopticspt30x-sdi firmwareptzopticsResearch use only. For defensive security, authorized penetration testing, and academic research only. Never execute exploit code against systems without explicit written authorization.
Detection & mitigation playbook
Vendor / applianceDetect
Inventory every ptzoptics pt30x-ndi firmware deployment and check each version against the affected-products list above.
Remediation status
No patch has shipped for CVE-2024-8957 yet — track the ptzoptics pt30x-ndi firmware advisory for a fixed release and apply the workarounds below in the meantime.
Mitigate without a patch
Stop passing untrusted input into the interpreter or shell: call the affected binary with an argument array rather than a composed command string, reject anything outside a strict allowlist of expected values, and run the component under an account that cannot reach beyond the work it legitimately does. Alongside that, restrict the management interface to trusted networks and apply the vendor's recommended configuration mitigations.
Frequently Asked Questions
Is CVE-2024-8957 being exploited in your environment?