Your RSA-2048 keys break in 2030. Find every one of them before attackers do.

CVE-2023-4346

HIGH

KNX devices that use KNX Connection Authorization and support Option 1 are, depending on the implementation, vulnerable to being locked and users being unable to reset them to gain…

Published
Aug 29, 2023
Updated
Jul 15, 2026
Affected
0 pkgs
Patched
None yet
Exploits
None indexed

EPSS Exploitation Probability

via FIRST.org ↗
0.5%probability of exploitation in next 30 days
Lower Risk38th percentile0.00%
0.00%0.33%0.66%0.98%0.0%0.5%Jan 26May 26Jul 26

EPSS (Exploit Prediction Scoring System) is a daily probability model maintained by FIRST.org. It estimates the likelihood a CVE will be exploited in production environments within the next 30 days, derived from real-world threat intelligence signals.

Description

KNX devices that use KNX Connection Authorization and support Option 1 are, depending on the implementation, vulnerable to being locked and users being unable to reset them to gain access to the device. The BCU key feature on the devices can be used to create a password for the device, but this password can often not be reset without entering the current password. If the device is configured to interface with a network, an attacker with access to that network could interface with the KNX installation, purge all devices without additional security options enabled, and set a BCU key, locking the device. Even if a device is not connected to a network, an attacker with physical access to the device could also exploit this vulnerability in the same way.

Affected Products

1 product · 1 configurations
Application
connection authorizationknx
all

Detection & mitigation playbook

Vendor / appliance
  1. Detect

    Inventory every knx connection authorization deployment and check each version against the affected-products list above. Because the exploit targets the running system rather than your application code, also watch for exploitation at the network and runtime layer — O3 flags the exploit behaviour from runtime telemetry and egress traffic even before a vulnerable build is confirmed.

  2. Remediation status

    No patch has shipped for CVE-2023-4346 yet — track the knx connection authorization advisory for a fixed release and apply the workarounds below in the meantime.

  3. Mitigate without a patch

    Cut exposure now: restrict the management/admin interface to trusted networks, segment the device, and apply the vendor's recommended configuration mitigations and any WAF/IPS signature. O3's runtime protection blocks the exploit chain at execution, holding the line on unpatched or end-of-life systems until you can patch.

  4. How O3 protects you

    O3 detects and blocks CVE-2023-4346 exploitation at runtime: eBPF exploit-chain detection, plus L7 egress monitoring that catches the post-exploitation callback and severs the attacker's outbound channel.

Tailored to CVE-2023-4346. Runtime protection reduces exposure until a permanent patch is applied and verified — it complements patching, it doesn't replace it.

Frequently Asked Questions

KNX devices that use KNX Connection Authorization and support Option 1 are, depending on the implementation, vulnerable to being locked and users being unable to reset them to gain access to the device. The BCU key feature on the devices can be used to create a password for the device, but this password can often not be reset without entering the current password. If the device is configured to interface with a network, an attacker with access to that network could interface with the KNX installation, purge all devices without additional security options enabled, and set a BCU key, locking th
O3 Security · Runtime Protection

Is CVE-2023-4346 being exploited in your environment?

O3's eBPF runtime sensors and L7 egress monitoring detect and block the CVE-2023-4346 exploit chain at execution — protecting unpatched and end-of-life systems until the vendor patch is applied.