Your RSA-2048 keys break in 2030. Find every one of them before attackers do.
🛡️
CISA KEV · ACTIVELY EXPLOITED
CRITICAL severity

CVE-2019-3929

CRITICAL

CVE-2019-3929 is a critical-severity (CVSS 9.8) Cross-site Scripting (XSS) vulnerability. It is in CISA's Known Exploited Vulnerabilities catalog (added 2022-04-15) — treat it as actively exploited and patch now. No vendor fix is recorded yet; mitigation options are listed below.

The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink…

Published
Updated
Affected
12 products
Patched
See advisory
Exploits
10 known
Exploitation data as of Oct 23, 2026 · OSV.dev, NVD, CISA KEV, FIRST.org (EPSS)

Exploitation Status

Actively exploited in the wild

  • Confirmed by CISA's Known Exploited Vulnerabilities catalog on 2022-04-15. Federal agencies were required to remediate by 2022-05-06.
  • CISA assesses this as automatable — exploitation doesn’t require manual, per-target effort, which raises the odds of mass scanning and opportunistic attacks.
  • A successful exploit gives an attacker total control of the affected component, not partial access.

Exploitation and automatability from CISA (KEV catalog and SSVC triage) for CVE-2019-3929.

EPSS Exploitation Probability

via FIRST.org ↗
99.0%probability of exploitation in next 30 days
Very High Risk0.00%
Lower risk than most CVEs100th percentile — riskier than 100% of all scored CVEsHighest risk
92.8%95.2%97.6%100.0%94.3%99.0%Apr 26Aug 26Oct 26

Probability of exploitation in the next 30 days, from FIRST.org EPSS.

How urgent is this, really

CVE-2019-3929 by exploitation likelihood (EPSS) against impact (CVSS). In the shaded patch-first corner (EPSS 50%+, CVSS 7.0+).

Where this sits among everything scored

Of 394,803 CVEs with a current EPSS score, this one falls in the ≥ 90% band (highlighted). Counts from FIRST.org, log-scaled.

Description

The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.

Affected Products

12 products · 12 configurations
OS
wepresent wipg-1000p firmwarebarco
1 version
2.3.0.10
OS
wepresent wipg-1600w firmwarebarco
< 2.4.1.19
range
OS
hd wireless presentation system firmwareblackbox
1 version
1.0.0.5
OS
am-100 firmwarecrestron
1 version
1.6.0.2
OS
am-101 firmwarecrestron
1 version
2.7.0.2
OS
sharelink 200 firmwareextron
1 version
2.0.3.4
Exploits & PoCs
10

Research use only. For defensive security, authorized penetration testing, and academic research only. Never execute exploit code against systems without explicit written authorization.

EDB-47924remotelinux✓ Verified

Barco WePresent - file_transfer.cgi Command Injection (Metasploit)

by Metasploit · Jan 15, 2020

EDB-46786webappshardware

Crestron AM/Barco wePresent WiPG/Extron ShareLink/Teq AV IT/SHARP PN-L703WA/Optoma WPS-Pro/Blackbox HD WPS/InFocus LiteShow - Remote Command Injection

by Jacob Baines · May 3, 2019

Detection & mitigation playbook

Vulnerability
  1. Detect

    Identify every host running the affected component and compare the installed build against the fixed version below — for source-built or distro-packaged software the version string, not a lockfile, is the source of truth (`dpkg -l`, `rpm -q`, or the binary's own `--version`).

  2. Remediation status

    No fixed release is recorded for CVE-2019-3929 yet. Track the upstream advisory, and apply the exposure-reduction steps below in the meantime.

  3. Mitigate without a patch

    Stop passing untrusted input into the interpreter or shell: call the affected binary with an argument array rather than a composed command string, reject anything outside a strict allowlist of expected values, and run the component under an account that cannot reach beyond the work it legitimately does.

How to detect CVE-2019-3929

A community-maintained Nuclei template exists for this CVE. You can scan for it directly:

nuclei -id cve-2019-3929 -u https://target
Template
Barco/AWIND OEM Presentation Platform - Remote Command Injection
Severity
critical
Impact
Successful exploitation of this vulnerability could lead to unauthorized remote code execution, potentially compromising the confidentiality, integrity, and availability of the affected system.
Remediation
Apply the latest security patches or updates provided by the vendor to mitigate this vulnerability.

Template by ProjectDiscovery nuclei-templates (_0xf4n9x_), MIT licensed. View the full template. Scan only systems you are authorised to test.

Frequently Asked Questions

The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.
O3 Security · Impact-Aware SCA

Is CVE-2019-3929 in your dependencies?

Find it across , including transitive dependencies.

Actively Exploited: CVE-2019-3929: XSS (Critical 9.8)