Your RSA-2048 keys break in 2030. Find every one of them before attackers do.

CVE-2019-25722

HIGH

Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that…

Published
Jun 2, 2026
Updated
Jun 17, 2026
Affected
0 pkgs
Patched
None yet
Exploits
None indexed

EPSS Exploitation Probability

via FIRST.org ↗
0.2%probability of exploitation in next 30 days
Lower Risk9th percentile0.00%

EPSS (Exploit Prediction Scoring System) is a daily probability model maintained by FIRST.org. It estimates the likelihood a CVE will be exploited in production environments within the next 30 days, derived from real-world threat intelligence signals.

Description

Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with direct device access can use the hard-coded credentials to access service and clinical accounts and alter device configuration, while a remote attacker can send malformed network packets to cause repeated device reboots, ultimately resulting in loss of network connectivity and disruption of patient monitoring.

Detection & mitigation playbook

Vulnerability
  1. Detect

    Scan your dependency tree (package-lock.json, pnpm-lock.yaml, requirements.txt, go.sum, etc.) for the affected component. O3's reachability analysis confirms whether the vulnerable code path is actually invoked in your application, so you act on real exposure instead of every transitive match.

  2. Remediation status

    No patched version of the affected component has shipped for CVE-2019-25722 yet. Where your build allows, override or pin the dependency away from the vulnerable range, and apply any maintainer-recommended mitigation.

  3. Mitigate without a patch

    If you can't upgrade right away: gate or disable the affected feature, validate untrusted input at the boundary, and avoid passing attacker-controlled data into the vulnerable path. O3's runtime protection blocks exploitation in production as an interim safeguard until the upgrade lands.

  4. How O3 protects you

    O3 pinpoints whether CVE-2019-25722 is reachable in your code and exactly where to fix it, then blocks exploitation in production at runtime until the patched version is deployed.

Tailored to CVE-2019-25722. Runtime protection reduces exposure until a permanent patch is applied and verified — it complements patching, it doesn't replace it.

Frequently Asked Questions

Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with direct device access can use the hard-coded credentials to access service and clinical accounts and alter device configuration, while a remote attacker can send malformed network packets to cause repeated device reboots, ultimately resulting in loss of network connectivity and disruption of patient mo