Your RSA-2048 keys break in 2030. Find every one of them before attackers do.
CISA KEV·Added 2021-11-03 — agencies required to remediate by 2022-05-03

CVE-2019-19356

HIGH

Netis WF2419 is vulnerable to authenticated Remote Code Execution (RCE) as root through the router Web management page. The vulnerability has been found in firmware version V1.2.31805…

Published
Feb 7, 2020
Updated
Jun 17, 2026
Affected
0 pkgs
Patched
None yet
Exploits
6 known

EPSS Exploitation Probability

via FIRST.org ↗
28.2%probability of exploitation in next 30 days
Moderate Risk98th percentile+0.21%
9.02%39.3%69.7%100.0%91.1%28.2%Jan 26May 26Jul 26

EPSS (Exploit Prediction Scoring System) is a daily probability model maintained by FIRST.org. It estimates the likelihood a CVE will be exploited in production environments within the next 30 days, derived from real-world threat intelligence signals.

Description

Netis WF2419 is vulnerable to authenticated Remote Code Execution (RCE) as root through the router Web management page. The vulnerability has been found in firmware version V1.2.31805 and V2.2.36123. After one is connected to this page, it is possible to execute system commands as root through the tracert diagnostic tool because of lack of user input sanitizing.

Affected Products

1 product · 2 configurations
OS
wf2419 firmwarenetis-systems
2 versions
1.2.318052.2.36123
Exploits & PoCs
6

Research use only. For defensive security, authorized penetration testing, and academic research only. Never execute exploit code against systems without explicit written authorization.

Detection & mitigation playbook

Vendor / appliance
  1. Detect

    Inventory every netis-systems wf2419 firmware deployment and check each version against the affected-products list above. Because the exploit targets the running system rather than your application code, also watch for remote code execution at the network and runtime layer — O3 flags the exploit behaviour from runtime telemetry and egress traffic even before a vulnerable build is confirmed.

  2. Remediation status

    No patch has shipped for CVE-2019-19356 yet — track the netis-systems wf2419 firmware advisory for a fixed release and apply the workarounds below in the meantime.

  3. Mitigate without a patch

    Cut exposure now: restrict the management/admin interface to trusted networks, segment the device, and apply the vendor's recommended configuration mitigations and any WAF/IPS signature. O3's runtime protection blocks the exploit chain at execution, holding the line on unpatched or end-of-life systems until you can patch.

  4. How O3 protects you

    O3 detects and blocks CVE-2019-19356 exploitation at runtime: eBPF exploit-chain detection, plus L7 egress monitoring that catches the post-exploitation callback and severs the attacker's outbound channel.

Tailored to CVE-2019-19356. Runtime protection reduces exposure until a permanent patch is applied and verified — it complements patching, it doesn't replace it.

Frequently Asked Questions

Netis WF2419 is vulnerable to authenticated Remote Code Execution (RCE) as root through the router Web management page. The vulnerability has been found in firmware version V1.2.31805 and V2.2.36123. After one is connected to this page, it is possible to execute system commands as root through the tracert diagnostic tool because of lack of user input sanitizing.
O3 Security · Runtime Protection

Is CVE-2019-19356 being exploited in your environment?

O3's eBPF runtime sensors and L7 egress monitoring detect and block the CVE-2019-19356 exploit chain at execution — protecting unpatched and end-of-life systems until the vendor patch is applied.